CLQXC - LOW MOISTURE SENSITIVE ZINC CHROMATE PRIMER YELLOW
- MSDS: CLQXC
- Manufacturer: FARWEST PAINT MANUFACTURING CO
- Product Name: LOW MOISTURE SENSITIVE ZINC CHROMATE PRIMER YELLOW
- National Stock Number: 8010-00-515-2208
Product Identification
Product ID:LOW MOISTURE SENSITIVE ZINC CHROMATE PRIMER YELLOW
MSDS Date:04/01/1992
FSC:8010
NIIN:00-515-2208
Status Code:A
MSDS Number: CLQXC
Responsible Party
TUKWILA, WA 98168
US
Emergency Phone: (800)424-9300
Info Phone: 206-244-8844
Preparer: HENRY SIMMONS
Cage: 6F266
Contractor
Telephone: 206-244-8844
Cage: 6F266
Ingredients
XYLENE
CAS: 1330-20-7
RTECS: ZE2100000
ACGIH TLV: 434 MG/M3;100 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
TOLUENE
CAS: 108-88-3
RTECS: XS5250000
OSHA PEL see Table Z-2
ACGIH TLV: 188 MG/M3;50 PPM
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
ZINC CHROMATE
CAS: 13530-65-9
RTECS: GB3290000
ACGIH TLV: 0.01 MG/M3
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Effects of Overexposure:INHALATION: EXCESSIVE EXPOSURES TO VAPORS OR
SPRAY MIST CAN RESULT IN HEADACHE, DIZZINESS, NAUSEA AND LOSS OF
CONSCIOUSNESS. SOME REPORTS HAVE ASSOCIATED REPEATED & PROLONGED
OCCUPATIONAL OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN &
NERVOUS DAMAGE. EYES: THIS MATERIAL MAY BE AN EYE IRRITANT.
Medical Cond Aggravated by Exposure:NONE; WHEN USED IN ACCORDANCE WITH
SAFE HANDLING INSTRUCTIONS. (SEE SECTION VIII)
First Aid
First Aid:SKIN: PROMPTLY WAS WITH SOAP AND WATER, REMOVE AND WASH ANY
CONTAINIMATED CLOTHING BEFORE REUSE EYES: FLUSH WITH LARGE
QUANTITIES OF WATER FOR 15 MINUTES AND SEEK MEDICAL ATTENTION
SWALLOWING: IF IN JESTED DO NOT INDUCE VOMITING: KEEP PERSON WARM
AND QUIET AND GET MEDICAL ATTENTION. ASPIRATION OF MATERIAL INTO
LUNGS CAN CAUSE CHEMICAL PNEUMONITIS WHICH CAN BE FATAL.
INHALATION: REMOVE VICTIM TO FRESH AIR IMMEDIATELY. IF RESPIRATORY
SYMPTONS DEVELOP, SEEK MEDICAL ATTENTION AT ONCE.
Fire Fighting
Flash Point Method:TCC
Flash Point:=1.7C, 35.F
Lower Limits:1.0%
Upper Limits:7.0%
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, OR WATER FOG.
Fire Fighting Procedures:FIREFIGHTERS AND OTHER EXPOSED TO VAPORS OR
PRODUCTS OF COMBUSTION SHOULD WEAR SELF-CONTAINED BREATHING
APPARATUS. EVACUATE AREA OF UNPROTECTED PERSONNEL. WEAR PROTECTIVE
CLOTHING.
Unusual Fire/Explosion Hazard:VAPORS MAY FORM AN EXPLOSIVE MIXTURE IN
AIR MAY BE IGNITED BY SPARKS, PILOT LIGHT, ETC. CLOSED CONTAINERS
MAY RUPTURE WHEN EXPOSED TO EXTREME HEAT. SKIN: THIS MATERIAL MAY
CAUSE IRRITATION, SENSITIZA TION, OR DEFATTING OF SKIN UPON
PROLONGED OR REPEATED CONTACT.
Accidental Release
Spill Release Procedures:REMOVE ALL SOURES OF IGNITION VENTILATE AREA.
ABSORB SPILL WITH AN ABSORBENT MATERIAL SUCH AS SAWDUST,
VERMICULITE OR SAND AND PLACE MATERIAL INTO A CLOSED CONTAINER. IF
LARGE SPILL, DIKE AREA TO PREV ENT THIS MATERIAL FROM ENTERING
WATER SYSTEMS OR SEWERS. WEAR PROTECTIVE EQUIPMENT DURING CLEANUP.
Handling
Handling and Storage Precautions:AVOID PROLONG OR REPEATED INHALATION
OF HEATED VAPORS OR SPRAY MIST. KEEP AWAY FROM HEAT OR OPEN FLAME.
THIS MATERIAL MAY CAUSE SENSITZATION. DO NOT GET INTO EYES, ON SKIN
OR CLOTHING. DO NOT ALLOW CO NTANIMATED CLOTHING TO CONTACT SKIN.
DO NOT WELD ON FULL OR EMPTY CONTAINERS. KEEP CONTAINERS CLOSED
Exposure Controls
Respiratory Protection:A CANISTER TYPE RESPIRATOR MUST BE WORN PREVENT
THE INHALATION OF VAPORS OR SPRAY MIST WHEN THE TLV OR PEL IS
EXCEEDED.
Ventilation:GENERAL VENTILATION IS REQUIRED DURING NORMAL USE. LOCAL
VENTILATION MAY BE REQUIRED DURING CERTAIN OPERATIONS TO KEEP
EXPOSURE LIMITS BELOW THE LIMITS.
Protective Gloves:CHEMICAL RESISTANT NITRILE, NEOPRENE OR RUBBER GLOVES
REQUIRED.
Eye Protection:WEAR FACE SHIELD OR CHEMICAL GOGGLES.
Other Protective Equipment:WEAR PROTECTIVE CLOTHING TO PREVENT SKIN
CONTACT. EYE WASH STATION AND SAFETY SHOWER SHOULD BE AVAILABLE.
Work Hygienic Practices:WASH HANDS BEFORE EATING OR SMOKING
Supplemental Safety and Health
Chemical Properties
Boiling Pt:=110.6C, 231.F
B.P. Text:231-284
Vapor Pres:22 MMHG@ 20C
Vapor Density:> AIR
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:NIL
Appearance and Odor:YELLOW LIQUID, AROMATIC ODOR
Percent Volatiles by Volume:58.62%
Stability
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG OXIDANTS. ACIDS, BASES AND EPOXY HARDNERS
UNDER UNCONTROLLED CONDITIONS
Stability Condition to Avoid:HEAT, SPARKS & OPEN FLAME. IF PRODUCT
CONTAINS ALUMINUM. MOISTURE IN CLOSED COINTAINERS WILL GENERATE
HYDROGEN GAS.
Hazardous Decomposition Products:INCOMPLETE COMBUSTION CAN YIELD CARBON
MONOXIDE AND TOXIC VAPORS
Disposal
Waste Disposal Methods:IF DISCARDED, THIS MATERIAL AND CONTAINERS
SHOULD BE TREATED AS HAZARDOUS WASTE BASED ON THE CHARACTERISTICS
OF IGNITABILTY AS DEFINED UNDER FEDERAL RCRA REGULATIONS (40 CFR
261). DISPOSAL OF THIS MAT ERIAL OR ITS CONTAINERS REQUIRES
COMPLIANCE WITH APPLICABLE, PACKGED AND RECORDKEEPING STANDARDS.
Other Information
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.